Teledyne LeCroy DL10-HCM Differential Probe, 1 GHz, 7.8X/17.5X/70X, 1 pF, 60 V, ProBus, DL-HCM Series

Our Part #45202.1

Condition:New

Mfr Part #DL10-HCM

Teledyne LeCroy DL10-HCM
Teledyne LeCroy
Teledyne LeCroy

Teledyne LeCroy DL10-HCM Differential Probe, 1 GHz, 7.8X/17.5X/70X, 1 pF, 60 V, ProBus, DL-HCM Series

Our Part #45202.1

Condition:New

Mfr Part #DL10-HCM

CA Prop 65
$7,025.00EACH
Calif. Prop 65

The 60 V Common Mode Differential Probes are the ideal probes for lower voltage GaN power conversion measurement with the highest accuracy, best CMRR, and lowest noise.

Features
  • Common Mode Differential Probe
  • 60 V of common mode and 80 V differential input range with 1 GHz of bandwidth, make these probes ideal for lower voltage GaN power conversion measurements. The 60 V of common mode is well suited for handling any float of the battery and bulk/absorption voltage during charging, while the 80 V differential input range provide margin for any overshoot.
  • The DL-HCM probes are calibrated for high-precision measurements to within 0.5% at DC and 0.1 dB flatness from DC to 100 MHz. This ensures high accuracy top and base voltage level measurement of pulse-width modulated signals. The Precision Gain Calibration capability furthers measurement precision by improving the gain accuracy and removing small offset drifts from the measurement configuration.
  • The Common Mode Rejection Ratio (CMRR) is exceptional to very high frequencies. This provides for the best measurement performance when measuring very fast slew rate (high dV/dt) PWM signals typical of GaN devices and systems. Exceptional CMRR, combined with low probe noise and high offset capability, makes the probes capable of measuring very small control signals floating on high common mode voltages.
  • The 60 V Common Mode Differential Probes provide the perfect combination of high performance and flexibility for connecting to any device under test. An optional accessory kit and high temperature solder-in tip are available for further connectivity options.

Brand: Teledyne LeCroy
Bandwidth: 1 GHz
Attenuation: 7.8X, 17.5X, 70X
Input Capacitance: 0.6 pF
Max Input Voltage: 60 V
Input Impedance: 200 kΩ
Interface: ProBus
Cable Length: 1.42 m
Series: DL-HCM Series
Operating Temperature Range: 0 to 50°C
Risetime: 350 ps
Series Compatibility: WaveSurfer 3000z, WaveSurfer 4000HD, HDOxxxx, WaveRunner 9000, WaveRunner 8000HD, MDA 8000HD, WavePro HD, WaveMaster / SDA / DDA 8 Zi-B, WaveMaster 8000HD and LabMaster 10 Zi-A
Type: Differential Probe
$7,025.00EACH